Project: TC4
Date: 7/29/2022 11:53:00 AM Pipe Segment Reference: TC4-M5-16 to TC4-M5-17
Street: Midgard Upstream MH: TC4-M5-16
Length Surveyed: 304.2 Downstream MH: TC4-M5-17
Run Number: Direction of Survey: Downstream
Height (Diameter): 8 Material: Vitrified Clay Pipe

Distance

Fault Observation

Time

Picture

7.0 Fracture Circumferential
Position:  6 To 1
Severity: None
Defect: 0
Percent: 0
Joint
Struct Weight: 2
00:24:50

7.5 Miscellaneous Water Level
Severity: None
Defect: 0
Percent: 10
00:00:44

11.4 Fracture Multiple
Position:  12 To 1
Severity: None
Cont Defect: S01
Defect: 0
Percent: 0
Joint
Remarks: N/L
Struct Weight: 4
00:01:56


Distance

Fault Observation

Time

Picture

21.1 Broken Soil Visible
Position:  9 To 1
Severity: None
Defect: 0
Percent: 0
Joint
Struct Weight: 5
00:03:46

21.1 Fracture Multiple
Position:  12 To 1
Severity: None
Cont Defect: F01
Defect: 0
Percent: 0
Joint
Remarks: N/L
Struct Weight: 4
00:04:02

36.0 Fracture Circumferential
Position:  12 To 1
Severity: None
Defect: 0
Percent: 0
Joint
Remarks: N/L
Struct Weight: 2
00:06:48


Distance

Fault Observation

Time

Picture

41.7 Broken Soil Visible
Position:  12 To 1
Severity: None
Defect: 0
Percent: 0
Struct Weight: 5
00:11:50

45.9 Fracture Multiple
Position:  12 To 1
Severity: None
Defect: 0
Percent: 0
Joint
Struct Weight: 4
00:12:57

69.4 Miscellaneous Abandoned Survey
Severity: None
Defect: 0
Percent: 0
Remarks: NEEDS JETTING
00:21:07


Distance

Fault Observation

Time

Picture

91.8 Fracture Circumferential
Position:  2 To 1
Severity: None
Defect: 0
Percent: 0
Joint
Struct Weight: 2
00:29:55

191.3 Roots Fine Lateral
Position:  9
Severity: None
Defect: 0
Percent: 0
Maint Weight: 1
00:35:06

191.3 Tap Break-in Activity
Position:  8
Severity: None
Size: 6
Defect: 0
Percent: 0
00:34:47


Distance

Fault Observation

Time

Picture

192.8 Fracture Multiple
Position:  7 To 1
Severity: None
Defect: 0
Percent: 0
Joint
Struct Weight: 4
00:36:33

203.0 Fracture Circumferential
Position:  11 To 2
Severity: None
Defect: 0
Percent: 0
Joint
Struct Weight: 2
00:38:08

218.0 Crack Longitudinal
Position:  12
Severity: None
Defect: 0
Percent: 0
Joint
Struct Weight: 2
00:39:29


Distance

Fault Observation

Time

Picture

244.8 Crack Multiple
Position:  12 To 1
Severity: None
Cont Defect: S02
Defect: 0
Percent: 0
Joint
Struct Weight: 3
00:41:25

258.7 Broken Soil Visible
Position:  12 To 1
Severity: None
Defect: 0
Percent: 0
Joint
Struct Weight: 5
00:44:03

258.7 Crack Multiple
Position:  12 To 1
Severity: None
Cont Defect: F02
Defect: 0
Percent: 0
Joint
Struct Weight: 3
00:43:34


Distance

Fault Observation

Time

Picture

263.8 Broken Soil Visible
Position:  12 To 1
Severity: None
Cont Defect: S03
Defect: 0
Percent: 0
Joint
Struct Weight: 5
00:45:23

267.2 Broken Soil Visible
Position:  12 To 1
Severity: None
Cont Defect: F03
Defect: 0
Percent: 0
Joint
Struct Weight: 5
00:46:08

273.5 Broken Soil Visible
Position:  12 To 1
Severity: None
Cont Defect: S04
Defect: 0
Percent: 0
Joint
Struct Weight: 5
00:47:38


Distance

Fault Observation

Time

Picture

275.9 Broken Soil Visible
Position:  12 To 1
Severity: None
Cont Defect: F04
Defect: 0
Percent: 0
Joint
Struct Weight: 5
00:48:29

283.7 Broken Soil Visible
Position:  12 To 1
Severity: None
Cont Defect: S05
Defect: 0
Percent: 0
Joint
Struct Weight: 5
00:49:57

295.2 Broken Soil Visible
Position:  12 To 1
Severity: None
Cont Defect: F05
Defect: 0
Percent: 0
Joint
Struct Weight: 5
00:50:45


Distance

Fault Observation

Time

Picture

301.9 Crack Circumferential
Position:  12 To 1
Severity: None
Defect: 0
Percent: 0
Struct Weight: 1
00:52:53

304.2 Access Point Manhole
Severity: None
Defect: 0
Percent: 0
Remarks: TC4-M5-17
00:53:32


Created with the report generator